Technical data:
Three kinds of shielding: aluminum foil; bare copper; aluminum foil+bare copper
Rated voltage: 300/500V
Test voltage: 2500V
Minimum bending radius: 0.3m≤L≤0.6M
Burning vertically test: GB/T1 8380.1-2001,
IEC60332-1:1993 test passed
Used under the normal conditions,temperature of conductor is lower then 70,
Temperature range:-15 to +70
TVVBG(intervvist) free suspension length exceed 80 meters,and the lift speed must not exceed 10m/s
Standards:
GB5023.6, IEC60227-6, EN50214
Applications:
As control and signal cable for elevator as well as moving nachine parts, its bending radius is smaller compared with round cables due to the closely packed shielded cores or bundles, It can be installed in dry and damp rooms. The copper shielded single or respectively bundled cores make this cable ideally suit for the situations where there are electromagnetic compatibiliy interference(EMC)
Structure:
Conductor: Fine strands of bare copper wire, acc. to VDE 0295,class 5
Insulation: special PVC
Colour: yellow, white, orange with black number digital coding
Bearing: steel rope
COAX: Optional
Sheath: flexible PVC , cold resistance, flame resistance
Colour: Grey(RAL 7001)